Product

Specialized Food Machinery Company

Outer Wall Insulation Materials

PRIME-CELL

Low-Emissivity Hybrid Insulation

High-efficiency, semi-non-combustible insulation product made using an eco-friendly manufacturing method

ITEM Cell 20T Cell 30T Cell 40T Cell 50T Cell 60T Cell 80T Cell 100T Cell 120T
General Model PC-0201 PC-0301 PC-0401 PC-0501 PC-0601 PC-0801 PC-1001 PC-1201
Thickness mm 20±0.5 30±0.5 40±0.5 50±0.5 60±0.5 80±0.5 100±0.5 120±0.5
U-value W/m²·K 0.31 ~ 0.44 0.23 ~ 0.29 0.15 ~ 0.22 0.10 ~ 0.15
Semi-non-combustible Model     PC-0403 PC-0503 PC-0603 PC-0803 PC-1003 PC-1203
Thickness mm     40±0.5 50±0.5 60±0.5 80±0.5 100±0.5 120±0.5
U-value W/m²·K     0.23 ~ 0.29 0.15 ~ 0.22 0.10 ~ 0.15
  • Common configuration】
  • Emittance: 0.049ε
  • Water Vapour Transmission : 3.1 g/㎡.24h
  • HCHO: N.D
  • VOC: <1mg/kg
  • U-value: Specify data values based on structure criteria
  20T 30T 40T 50T 60T 80T
Size 20Tx1Mx20M 30Tx1Mx15M 40Tx1Mx10M 50Tx1Mx8M 60Tx1Mx7M 80Tx1Mx2M (plate type)
General
Semi-noncombustible    
  • 【Common configuration】
  • Structure: AL Foil + PE Foam + AL Foil + PE Foam + AL Foil
  • Option: ***T/a: adhesive

POINT

Low-Emissivity Hybrid Insulation Point

 
01
Economic efficiency
Easy construction reduces construction time and cost
02
Constructability
Increases work efficiency being lightweight
and easy to cut and attach
 
 
03
Spatiality
About 60~70% thinner than conventional
insulation materials (e.g. urethane, Styrofoam, etc.)
but boasts the same performance
04
Insulation life
Semi-permanent insulation with
no changes over time
 
 
05
Performance certification
Certified in accordance with the Ministry of Land,
Infrastructure and Transport Notice
[Energy Saving Design Standards for Buildings]

PATENT

Patent Click Method

Patented product made using the half-lap joint technique (Patent No. 30-0496698)
necessary to prevent any gaps when installing the insulation material. The half-lap joint method.
without the shortcomings of the general method in that it prevents heat and cold bridges, is applied.

ECO-FRIENDLY

Eco-friendly Manufacturing Method

High-efficiency
insulation

60-70% thinner but the same level of insulation performance

Eco-friendly
manufacturing method

Chemical adhesives (HCHO, TVOCs, etc.) not required, due to the application of a thermosetting method

Semi-non-
combustible

Safe material without any toxic gas emission in the event of a fire

Environmental
report

Environmental impact on the entire process, evaluated and certified based on 7 indicators

METHOD

Construction Method

  • The substrate should be made flat, smooth and clean by removing protrusions, such as nails, wires, and mortar, as the presence of such materials will likely impede the installation process.
  • Install the insulation material according to the arrangement plan. Use a cutter to cut the insulation material straight on site.
  • Overlap two pieces of the insulation material during installation. If there is a need to connect the insulation materials, make sure the joints are away from each other.
  • When attaching the insulation material to the substrate, smooth out the surface of the substrate first, and make sure that the two materials are in close contact with each other.
    (Depending on the situation of the installation site, it is possible to use an adhesive type or securing pieces (cap stapler, fasteners, etc.).)
  • When using securing pieces (cap stapler, etc.), use 9 to 15 pieces per 1㎡ and make sure that the aluminum surface is not damaged during installation.
  • The joint part of the insulation material should not have any gap, and this is ensured by using tape or adhesive.
    Reinforce the area where the half-lap joint technique cannot be applied with an adequate insulation material.

TOOLS

Construction Tools

 
  • 시공전용테이프

    Construction-only
    tape

  • 칼블럭,화스너

    Screw anchors,
    Fasteners

  • 콘크리트타카건,타카핀

    Concrete stapler gun,
    Stapler pins

  • 캡타카건,타카핀

    Cap stapler gun,
    Stapler pins

NOTICE

Prime Cell Notice

  • Precautions & Instructions
    • Remove all foreign substances from the wall to prevent interference with the installation of the insulation material and dry the wall completely.
    • The insulation material should be processed on a clean, flat surface, but make sure to use appropriate tools to process it into correct dimensions without any damage to the material.
    • Use a designated tape to prevent gaps in the joints of the insulation material.
      When installing multiple layers of the insulation material, the joints should not be aligned.
    • As for the corners, etc., make sure that there is no gap with the wall or areas that are not insulated.
    • If there is any loss or damage to the insulation material due to the installation of the finishing material and the structure of any installations, fill the area with foam (urethane, etc.) and attach tape.
      Then, if there aren’t any problems, clean up the site and finish off the work.
  • Precautions & Instructions for Transport, Storage and Handling
    • Be careful when transporting and handling the insulating material to prevent damage.
    • Be careful when transporting and handling the insulating material to prevent damage. Insulation materials should not be directly exposed to sunlight, rain, or wind and should be stored in a well-ventilated place with low humidity and good ventilation. They should be stored according to their respective uses, type, characteristics and shape.
    • Do not place any heavy objects on the insulating material and do not leave it outside for more than 2 months.
    • The exposed surface of the insulation material should be marked with a joint, etc., and the loading height should be no more than 2m.
    • Always store insulation products upright in a way that they do not come into direct contact with the ground.
  • Precautions & Instructions After Installation
    • Prevent excessive impact and keep it clean.